WARNING:
IF THE INFORMATION IN THESE INSTRUC-
TIONS ARE NOT FOLLOWED EXACTLY, A FIRE
OR EXPLOSION MAY RESULT CAUSING PROP-
ERTY DAMAGE, PERSONAL INJURY OR LOSS
OF LIFE.
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
INSTALLATION:
INSTALLATION AND SERVICE MUST BE PER-
FORMED BY A QUALIFIED INSTALLER, SER-
VICE AGENCY OR LICENSED GAS SUPPLIER.
WHAT TO DO IF YOU SMELL GAS:
• DO NOT TRY TO LIGHT ANY APPLIANCE.
• DO NOT TOUCH ANY ELECTRICAL
SWITCHES.
• DO NOT USE THE PHONE IN YOUR
BUILDING. IMMEDIATELY CALL YOUR GAS
SUPPLIER FROM A NEIGHBOR’S PHONE.
• FOLLOW YOUR GAS SUPPLIER’S
INSTRUCTIONS.
• IF YOU CANNOT REACH YOUR GAS
SUPPLIER, CALL THE FIRE DEPARTMENT.
AVERTISSEMENT:
ASSUREZ-VOUS DE BIEN SUIVRE LES IN-
STRUCTIONS DANS CETTE NOTICE POUR
REDUIRE AU MINIMUM LE RISQUE D’INCENDIE
OU POUR EVITER TOUT DOMMAGE MATERIEL,
TOUTE BLESSURE OU MORTALIT’E.
NE PAS ENTREPOSER NI UTILISER D’ESSENCE
NI OU LIQUIDES INFLAMMABLES DANS LE
VOISINAGE DE CET APPAREIL OU DE TOUT
AUTRE APPAREIL.
L’INSTALLATION LE SERVICE DOIVENT
ETRE EXECUTES PAR UN INSTALLATEUR
QUALIFIE, AGENCE DE SERVICE OU LE
FOURNISSEUR DE GAZ.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE
GAZ.
• NE PAS TENTER D’ALLUMER L’APPAREIL
• NE TOUCHEZ A AUCUN INTERRUPTEUR.
• NE PAS VOUS SERVIR DES TELEPHONES
SE TROUVANT DANS LE BATIMENT OU VOUS
VOUS TROUVEZ.
APPELEZ IMMEDIATEMENT VOTRE
FOURNISSEUR DE GAZ CHEZ UN VOISIN.
SUIVEZ LES INSTRUCTIONS DU FOURNISSEUR.
• SI VOUS NE POUVEZ REJOINDRE LE
FOURNISSEUR DE GAZ, APPELEZ LE SER-
VICE DES INCENDIES.
US
Warnock Hersey
C
GF 200 DV
Lillehammer
Gas Heater
Installation
and
Operation
Instructions
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - Gas Heater

WARNING:IF THE INFORMATION IN THESE INSTRUC-TIONS ARE NOT FOLLOWED EXACTLY, A FIREOR EXPLOSION MAY RESULT CAUSING PROP-ERTY DAMAGE, PERSONAL INJURY OR

Pagina 2 - Welcome to Jøtul

10Co-linear Hearthmount InstallationThe Jøtul GF 200 DV Lillehammer may be ventedthrough a masonry fireplace using Simpson Dura-Vent Chimney Liner Con

Pagina 3 - Direct Vent Gas Heater

11Masonry or Prefabricated ChimneyConversionThe GF200 DV Lillehammer is approved for use withSimpson Dura-vent Chimney Kit #934 in a masonrychimney or

Pagina 4 - Specifications

12Horizontal Venting (Horizontal Termination)• The maximum horizontal run made directly offthe rear of the stove into a standard horizontalcap (#984 o

Pagina 5 - General Information

13Wall Shield InstallationWhen horizontally venting directly off the rear of thestove, install the decorative Wall Shield #129349,(included in the sto

Pagina 6 - Safety Information

14Vent Termination RequirementsFigure 15. Vent Terminal Clearances - National Fuel Gas CodeA = Clearance above grade, veranda, porch , deck, orbalcony

Pagina 7 - Clearance to Combustibles

15Tools Required:• 1/4” Nut driver• 7/16” and 1/2” open end wrench• Torx T-20 or slotted screwdriver.Fuel Conversion Kit Contents:• 1 regulator t

Pagina 8 - Venting Requirements

16Gas Conversion ProcedureSee Figure 29, page 25 for parts identification.1. Turn off gas supply to the stove.2. Remove the stove Top Plate (3).3. Rem

Pagina 9 - HORIZONTAL RUN

17Connect the Gas SupplyThe gas supply line connection is made to the valvejust inside the left rear leg. The gas supply lineshould be 3/8" npt w

Pagina 10

18Leak Test:• Mix a 50-50 solution of water and dish soap.• Light appliance- see lighting instructions on page21 of this manual or on the stove’s rati

Pagina 11 - Conversion

19Derating Procedure:To derate this unit, install the appropriate orifice asshown in the High Altitude chart.1. Remove the two ¼” hex head screw that

Pagina 12

2Welcome to Jøtul...Congratulations on the purchase of your newJøtul GF 200 DV Lillehammer - a direct vented gasheater especially designed and approve

Pagina 13 - Wall Shield Installation

20Install the Log SetThe Lillehammer is equipped with a one piece logset and is packaged in bubble wrap inside thefirebox. The log set must be remove

Pagina 14 - Vent Termination Requirements

211(25mm)3/8(8mm)Min.1/8(3mm)Min.IgnitorThermopileThermocoupleChecking the System1. Purging the Gas Line: When lighting the appli-ance for the fir

Pagina 15 - Gas Conversion

223. Burner Adjustment: The Lillehammer isequipped with a variable gas control valve. thatprovides easy adjustment of the flame heightappearance an

Pagina 16 - Gas Conversion Procedure

23With proper care and maintenance, your Jøtulgas stove will provide you with many years ofservice. If you experience any problems with JøtulGF 200 D

Pagina 17 - Connect the Gas Supply

24Maintenance RecordJøtul GF 200 LillehammerDirect Vent StoveModel:Serial Number: __________________________Date of Purchase: _______________________

Pagina 18 - Gas Pressure

25321Illustrated Parts ListGF 200 DV Lillehammer3940Figure 29.12A2022423221941211101336CAB3738D4143421355341517181614272620233282529303132

Pagina 19 - High Altitude Adjustment

2610 Glass Frame 1293169211 Glass Gasket (7/16” tadpole) 12912412 Glass Clip 129135Glass Frame Assembly 15433712A Latch Keeper 12914913 Glass 12911314

Pagina 20 - Install the Log Set

277. Push in gas control knob slightly and turncounterclockwise to “PILOT”.8. Push in control knob all the way and hold in.Immediately light the pil

Pagina 21 - Thermostat of Remote Control

Jøtul ASAP.O. Box 1411N-1602 Fredrikstad, NorwayJøtul North America400 Riverside StreetPortland, ME 04104137743 1.03Stoves and fireplaces must be

Pagina 22 - Operation of Appliance

3Table of ContentsSpecifications ... 3General Information ... 5Safet

Pagina 23 - Maintenance

4Jøtul GF 200 DV LillehammerSpecificationsFigure 1. Dimensional Views - GF 200 DVLillehammerGF 200 DV Lillehammer Options• Fuel Conversion Kit - NG..

Pagina 24 - Maintenance Record

5DO NOT OPERATE THE LILLEHAMMERGAS STOVE WITH THE GLASS FRONTREMOVED, CRACKED OR BROKEN.REPLACEMENT OF THE GLASS SHOULDBE DONE BY A LICENSED OR QUALIF

Pagina 25 - Illustrated Parts List

6Locating the StoveIn selecting the location, the aesthetic and func-tional use of the appliance are primary concerns.However, proper venting systems

Pagina 26 - ( 3/8”NTP to 5/8”) 129129

7Clearance to CombustiblesMinimum Stove ClearanceRear 0” (0mm)Ceiling 17” (432mm)Corner 2” (51mm)Right Side 2” (51mm)Left Side *10” (255mm)* Necessar

Pagina 27 - LIGHTING INSTRUCTIONS

8Install the Exhaust Restrictor Plate1. Remove the Top Plate to access the Glass Panel.2. Release the Glass Panel latches and lift the panelstraight

Pagina 28 - Jøtul North America

935 Ft.(10.67 m)30 Ft.(9.14 m)25 Ft.(7.62 m)20 Ft.(6.10 m)15 Ft.(4.57 m)5 Ft.(1.52 m) 1 Ft.(.30 m)10 Ft.(3.05 m)10 Ft.(3.05 m)5 Ft.(1.52 m)VERTICAL RU