WARNING:IF THE INFORMATION IN THESE INSTRUC-TIONS ARE NOT FOLLOWED EXACTLY, A FIREOR EXPLOSION MAY RESULT CAUSING PROP-ERTY DAMAGE, PERSONAL INJURY OR
10Co-linear Hearthmount InstallationThe Jøtul GF 200 DV Lillehammer may be ventedthrough a masonry fireplace using Simpson Dura-Vent Chimney Liner Con
11Masonry or Prefabricated ChimneyConversionThe GF200 DV Lillehammer is approved for use withSimpson Dura-vent Chimney Kit #934 in a masonrychimney or
12Horizontal Venting (Horizontal Termination)• The maximum horizontal run made directly offthe rear of the stove into a standard horizontalcap (#984 o
13Wall Shield InstallationWhen horizontally venting directly off the rear of thestove, install the decorative Wall Shield #129349,(included in the sto
14Vent Termination RequirementsFigure 15. Vent Terminal Clearances - National Fuel Gas CodeA = Clearance above grade, veranda, porch , deck, orbalcony
15Tools Required:• 1/4” Nut driver• 7/16” and 1/2” open end wrench• Torx T-20 or slotted screwdriver.Fuel Conversion Kit Contents:• 1 regulator t
16Gas Conversion ProcedureSee Figure 29, page 25 for parts identification.1. Turn off gas supply to the stove.2. Remove the stove Top Plate (3).3. Rem
17Connect the Gas SupplyThe gas supply line connection is made to the valvejust inside the left rear leg. The gas supply lineshould be 3/8" npt w
18Leak Test:• Mix a 50-50 solution of water and dish soap.• Light appliance- see lighting instructions on page21 of this manual or on the stove’s rati
19Derating Procedure:To derate this unit, install the appropriate orifice asshown in the High Altitude chart.1. Remove the two ¼” hex head screw that
2Welcome to Jøtul...Congratulations on the purchase of your newJøtul GF 200 DV Lillehammer - a direct vented gasheater especially designed and approve
20Install the Log SetThe Lillehammer is equipped with a one piece logset and is packaged in bubble wrap inside thefirebox. The log set must be remove
211(25mm)3/8(8mm)Min.1/8(3mm)Min.IgnitorThermopileThermocoupleChecking the System1. Purging the Gas Line: When lighting the appli-ance for the fir
223. Burner Adjustment: The Lillehammer isequipped with a variable gas control valve. thatprovides easy adjustment of the flame heightappearance an
23With proper care and maintenance, your Jøtulgas stove will provide you with many years ofservice. If you experience any problems with JøtulGF 200 D
24Maintenance RecordJøtul GF 200 LillehammerDirect Vent StoveModel:Serial Number: __________________________Date of Purchase: _______________________
25321Illustrated Parts ListGF 200 DV Lillehammer3940Figure 29.12A2022423221941211101336CAB3738D4143421355341517181614272620233282529303132
2610 Glass Frame 1293169211 Glass Gasket (7/16” tadpole) 12912412 Glass Clip 129135Glass Frame Assembly 15433712A Latch Keeper 12914913 Glass 12911314
277. Push in gas control knob slightly and turncounterclockwise to “PILOT”.8. Push in control knob all the way and hold in.Immediately light the pil
Jøtul ASAP.O. Box 1411N-1602 Fredrikstad, NorwayJøtul North America400 Riverside StreetPortland, ME 04104137743 1.03Stoves and fireplaces must be
3Table of ContentsSpecifications ... 3General Information ... 5Safet
4Jøtul GF 200 DV LillehammerSpecificationsFigure 1. Dimensional Views - GF 200 DVLillehammerGF 200 DV Lillehammer Options• Fuel Conversion Kit - NG..
5DO NOT OPERATE THE LILLEHAMMERGAS STOVE WITH THE GLASS FRONTREMOVED, CRACKED OR BROKEN.REPLACEMENT OF THE GLASS SHOULDBE DONE BY A LICENSED OR QUALIF
6Locating the StoveIn selecting the location, the aesthetic and func-tional use of the appliance are primary concerns.However, proper venting systems
7Clearance to CombustiblesMinimum Stove ClearanceRear 0” (0mm)Ceiling 17” (432mm)Corner 2” (51mm)Right Side 2” (51mm)Left Side *10” (255mm)* Necessar
8Install the Exhaust Restrictor Plate1. Remove the Top Plate to access the Glass Panel.2. Release the Glass Panel latches and lift the panelstraight
935 Ft.(10.67 m)30 Ft.(9.14 m)25 Ft.(7.62 m)20 Ft.(6.10 m)15 Ft.(4.57 m)5 Ft.(1.52 m) 1 Ft.(.30 m)10 Ft.(3.05 m)10 Ft.(3.05 m)5 Ft.(1.52 m)VERTICAL RU